Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Chem Inf Model ; 64(3): 621-626, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38276895

RESUMO

Using a combination of multisite λ-dynamics (MSλD) together with in vitro IC50 assays, we evaluated the polypharmacological potential of a scaffold currently in clinical trials for inhibition of human neutrophil elastase (HNE), targeting cardiopulmonary disease, for efficacious inhibition of Proteinase 3 (PR3), a related neutrophil serine proteinase. The affinities we observe suggest that the dihydropyrimidinone scaffold can serve as a suitable starting point for the establishment of polypharmacologically targeting both enzymes and enhancing the potential for treatments addressing diseases like chronic obstructive pulmonary disease.


Assuntos
Polifarmacologia , Humanos , Mieloblastina , Proteínas Secretadas Inibidoras de Proteinases
2.
Biomolecules ; 13(8)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37627277

RESUMO

Cancer cells often adapt to targeted therapies, yet the molecular mechanisms underlying adaptive resistance remain only partially understood. Here, we explore a mechanism of RAS/RAF/MEK/ERK (MAPK) pathway reactivation through the upregulation of RAF isoform (RAFs) abundance. Using computational modeling and in vitro experiments, we show that the upregulation of RAFs changes the concentration range of paradoxical pathway activation upon treatment with conformation-specific RAF inhibitors. Additionally, our data indicate that the signaling output upon loss or downregulation of one RAF isoform can be compensated by overexpression of other RAF isoforms. We furthermore demonstrate that, while single RAF inhibitors cannot efficiently inhibit ERK reactivation caused by RAF overexpression, a combination of two structurally distinct RAF inhibitors synergizes to robustly suppress pathway reactivation.


Assuntos
Regulação para Cima , Simulação por Computador , Regulação para Baixo , Conformação Molecular , Resistência a Medicamentos
3.
Cell Syst ; 7(2): 161-179.e14, 2018 08 22.
Artigo em Inglês | MEDLINE | ID: mdl-30007540

RESUMO

Clinically used RAF inhibitors are ineffective in RAS mutant tumors because they enhance homo- and heterodimerization of RAF kinases, leading to paradoxical activation of ERK signaling. Overcoming enhanced RAF dimerization and the resulting resistance is a challenge for drug design. Combining multiple inhibitors could be more effective, but it is unclear how the best combinations can be chosen. We built a next-generation mechanistic dynamic model to analyze combinations of structurally different RAF inhibitors, which can efficiently suppress MEK/ERK signaling. This rule-based model of the RAS/ERK pathway integrates thermodynamics and kinetics of drug-protein interactions, structural elements, posttranslational modifications, and cell mutational status as model rules to predict RAF inhibitor combinations for inhibiting ERK activity in oncogenic RAS and/or BRAFV600E backgrounds. Predicted synergistic inhibition of ERK signaling was corroborated by experiments in mutant NRAS, HRAS, and BRAFV600E cells, and inhibition of oncogenic RAS signaling was associated with reduced cell proliferation and colony formation.


Assuntos
Resistencia a Medicamentos Antineoplásicos , Neoplasias/tratamento farmacológico , Inibidores de Proteínas Quinases/química , Inibidores de Proteínas Quinases/farmacologia , Transdução de Sinais/efeitos dos fármacos , Quinases raf/antagonistas & inibidores , Proteínas ras/metabolismo , Linhagem Celular Tumoral , Humanos , Sistema de Sinalização das MAP Quinases/efeitos dos fármacos , Simulação de Acoplamento Molecular , Mutação/efeitos dos fármacos , Neoplasias/genética , Neoplasias/metabolismo , Multimerização Proteica/efeitos dos fármacos , Termodinâmica , Quinases raf/química , Quinases raf/metabolismo , Proteínas ras/genética
4.
IET Nanobiotechnol ; 7(1): 1-6, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23705287

RESUMO

Precise detection of 3-hydroxybutyrate (HB) in biological samples is of great importance for management of diabetic patients. In this study, an HB biosensor based on single-walled carbon nanotubes (SWCNTs)-modified screen-printed electrode (SPE) was developed to determine the concentration of HB in serum. The specific detecting enzyme, HB dehydrogenase, was physically immobilised on SWCNTs deposited on the surface of SPEs. The electrochemical measurement of HB that involved cyclic voltammetry was based on the sAgnal produced by j3-nicotinamide adenine dinucleotide (NADH), one of the products of the enzymatic reaction. The application of SWCNT reduced the oxidation potential of NADH to about -0.05 V. Electrochemical measurements showed that the response of this biosensor had relevant good linearity in the range of 0.1-2 mM with a low detection limit of 0.009 mM. Investigation of biosensor response in the presence of interfering molecules verified its specificity. Furthermore, the study of long-term stability demonstrated the acceptable efficiency of this biosensor for about 100 days.


Assuntos
Ácido 3-Hidroxibutírico/análise , Técnicas Biossensoriais/instrumentação , Enzimas Imobilizadas/química , Hidroxibutirato Desidrogenase/química , Nanotubos de Carbono/química , Ácido 3-Hidroxibutírico/sangue , Ácido 3-Hidroxibutírico/metabolismo , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/instrumentação , Eletrodos , Estabilidade Enzimática , Enzimas Imobilizadas/metabolismo , Humanos , Hidroxibutirato Desidrogenase/metabolismo , Limite de Detecção , NAD/análise , NAD/química , NAD/metabolismo
5.
Biosens Bioelectron ; 43: 336-47, 2013 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-23356999

RESUMO

Gold nanoparticles (AuNPs) with optical and electrochemical distinctiveness as well as biocompatibility characteristics have proven to be powerful tools in nanomedicinal application. This review article discusses recent advances in the application of AuNPs as label in bioanalytical devices, especially electrochemical immunosensors, rapid and point-of-care (PoC) tests. A crucial assessment regarding implementation of different formats of antibodies allowing rapid and sensitive analysis of a range of analytes is also provided in this study. In addition to this, different approaches to minimize antibodies into Fab, scFv or even single-domain antibody fragments like VHHs will be reviewed. Given the high level of target specificity and affinity, such biomolecules are considered to be excellent elements for on-site or PoC analysis.


Assuntos
Anticorpos/química , Anticorpos/imunologia , Técnicas Biossensoriais/instrumentação , Ouro/química , Imunoensaio/instrumentação , Nanopartículas/química , Desenho de Equipamento , Análise de Falha de Equipamento , Coloração e Rotulagem
6.
Mol Biol Rep ; 40(3): 2327-34, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23187739

RESUMO

3-Hydroxybutyrate, one of the main blood ketone bodies, has been considered as a critical indicator for diagnosis of diabetic ketoacidosis. Biosensors designed for detection of 3-hydroxybutyrate with advantages of precision, easiness and speedy performance have attracted increasing attention. This study attempted to develop a 3-hydroxybutyrate dehydrogenase-based biosensor in which single-walled carbon nanotubes (SWCNT) was used in order to immobilize the cofactor, NAD(+), on the surface of screen-printed electrode. The formation of NAD(+)-SWCNT conjugates was assessed by electrochemistry and electron microscopy. Cyclic voltammetry was used to analyze the performance of this biosensor electrochemically. The considerable shelf life and reliability of the proposed biosensor to analyze real sample was confirmed by this method. The reduction in the over potential of electrochemical oxidation of NADH to -0.15 V can be mentioned as a prominent feature of this biosensor. This biosensor can detect 3-hydroxybutyrate in the linear range of 0.01-0.1 mM with the low detection limit of 0.009 mM. Simultaneous application of screen-printed electrode and SWCNT has made the biosensor distinguished which can open new prospects for detection of other clinically significant metabolites.


Assuntos
Ácido 3-Hidroxibutírico/química , Técnicas Biossensoriais/métodos , Eletroquímica/métodos , Eletrodos , Nanotubos de Carbono/química , NAD/química , Nanotubos de Carbono/ultraestrutura , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...